  The equipment includes a brand computer, software system, precision voltage internal resistance measuring instrument, scanning code mechanism and batch feeding device, automatic binning of the manipulator, automatic unloading, and other devices.

  According to the AC internal resistance, open circuit voltage, and other parameters of the lithium battery, the battery is accurately grouped according to the performance parameters of each function, and the maximum number of one-time binning pairs are 8 groups, which improves the consistency of pack battery quality and paired cell performance.

  The acquisition of AC internal resistance and open circuit voltage can be automatically collected by using the high-precision internal resistance instrument daily BT3562A that comes with this equipment, automatic control of the sorting process, easy operation, and manual participation, which ensures the accuracy of test parameters and the reliability of the matching process and improves and guarantees the performance quality of pack products.

  High degree of automation, simple operation, hopper feeding, easy operation, can test and assemble about 600 batteries per hour, can effectively improve production efficiency, reduce production costs.

➢ The performance data of the battery cell tested by the system implements the database management mode, long-term preservation, and strong traceability. With the data analysis function of the software, the long-term monitoring and analysis of product performance and quality is carried out to guide the improvement of R&D formulas and improve the production process.

    ➢ The data is collected by the industrial computer, and the curve chart and bar chart are automatically generated, and the system has a database function             to trace the historical data and export it.

The applicable battery specifications and incoming material requirements:

  1. Square 5 0*160*118, 36*130*200, 30*130*200 battery;
  2. The positive and negative poles are clean and dirty-free.

The technical parameters of the equipment description:

  • Power supply: 220V, 2KW.
  • Air supply: 0.5 to 0.6 Mpa (dry air).
  • Sorting efficiency: ≥10PPM.
  • Product pass rate: ≥99%.
  • Equipment grafting rate: ≥95%.
  • Sorting pass rate: ≥98%.  ➢Sorting accuracy: 99.9%.
  • Secondary test: edge voltage deviation ± 0.1mV, internal resistance deviation ±0 05mΩ。
  • Sorting parameters: open circuit voltage, AC internal resistance.
  • Instrument: Precision voltage internal resistance tester.
  • Equipment weight:300KG.

The equipment configuration list:

S.

No.

 

Description

 

brand

1

cylinder

AIRTAC

2

Solenoid valves

AIRTAC

3

Linear guides

HIWIN

4

Relays

OMRON

5

Motion control card

Resai Intelligence

6

inductor

Jia Zhun

7

Computer host

R&D Industrial Control 机

8

Test gauges

Japanese BT3562A

9

Software systems

Battery automatic test sorting system

Other requirements

  • The appearance color of the equipment is international standard warm gray 1C.
  • Measure 1000mm from the outer wall of the machine, and the noise of the equipment ≤ 80db.

S.No.

Content

1

Dangerous parts such as high temperature and high pressure of the equipment have corresponding protection devices and warning signs

2

During normal operation, the equipment will not appear to smoke, abnormal noise, air leakage, leakage, sparks, and open flames

 

3

The equipment has emergency switch protection, overvoltage protection, over-current protection, leakage protection, short-circuit protection, vacuum pump/motor overload protection, over-temperature protection, and sound and light alarm protection functions

 

4

An emergency stop switch is installed in a conspicuous position at the installation site of the equipment to carry out emergency stop operations in the event of an emergency with the equipment

 

5

The equipment is safe and reliable, the appearance is neat, and the maintenance and inspection are convenient, in the case of system failure or protective device failure, the equipment cannot start or immediately stop working, while alarming

6

The main components of the equipment are reliable devices and are not worn parts

  • The equipment complies with national safety standards of the relevant equipment.