Semco SI BMST 1-16S (40A 120A)/ 1-24S (40A 120A)/1-32S (40A 150A) WITH CABINET
Table Of Content
- Overview
- Main Performance Of Test Equipment
- Technical Parameter
- Equipment Parameters
- Machine Working
Introduction To The Scope And Function Of The Equipment:
- Scope of application: mainly used to detect whether the functional indicators of the power battery protection board are in the parameter range In order to provide staff with a set of testing standards. It is mainly used to test the power battery protection board of the protection board manufacturer and the power battery
- Function introduction: PBTS protection board test system, is divided into two types: Quick test and precise
Main Performance Of Test Equipment:
- Routine test items: Internal resistance test, overcharge and over-discharge test, overcharge recovery and over-discharge recovery test, over Current test (charge over current and discharge over current) overcharge protection voltage, overcharge recovery voltage, over-discharge protection voltage, over discharge recovery voltage, over current protection,
- Unique test items: Short-circuit protection test (refers to the real short-circuit protection test in microseconds). Single-cell self-consumption test (refers to the true and accurate self-consumption of each cell). Equalization current and equalization voltage (can accurately capture equalization current and equalization opening voltage). Infrared scanning (bar code scanning) scans the ID number of each protection board and stores the
- Types of protection boards that support testing: Lithium iron phosphate, ternary lithium Cobalt oxide, and lithium.
Technical Parameter:
- High current module: the current level is 120A, current accuracy is 1A.
- Voltage module: voltage range 5-5V, programmable output 0.5-5V, voltage accuracy 5mV.
- Short circuit module: supercapacitor, fully analog pack the battery voltage instantly short-circuits the protection board to accurately capture the short-circuit time.
Equipment Parameters:
Test items |
Test Range | Precision |
Number of test strings | 1-16 string | |
The reference voltage | Ternary lithium battery(3.8V), lithium iron phosphate (3.0V) | |
Overcharge protection voltage | 0.5-5V | ±5mV |
Over-discharge protection voltage | 0.5-5V | ±5mV |
Overcharge recovery voltage(Self-recovery) | 0.5-5V | ±5mV |
Over-discharge recovery voltage(Self-recovery) | 0.5-5V | ±5mV |
Overcharge protection current | 1-40A | ±0.1A |
Over-discharge protection current | 1-120A | ±0.1A |
Balanced opening voltage | 0.5-5V | ±5mV |
Balance real-time current | 0-1000mA | ±1mA |
Over-current protection delay | 0-15S | ±1mS |
Overcharge protection delay | 0-20S | ±1mS |
Over-discharge protection delay | 0-20S | ±1mS |
Single-cell self- consumption | 0-500uA | ±1uA |
Loop resistance | 0-500mΩ | ±1mΩ |
Short circuit protection (6 strings or more) | 0-9999us | ±1uS |
Scope of application | All hardware solution protection boards and some software boards in the market(Special test items need to be communicated) |
Product Appearance Structure And Working Environment Requirements:
- Equipment size: the volume of the instrument itself is 420×410×200mm, net weight 15KG.
- Working environment: working power requires mains AC220V input, power supply fluctuation range (170-260V), working environment temperature -10°C to 40°C, working humidity 10%~90%, maximum power 600W only appears in the case of high current.