Semco SI CY 05C SM 33140- Hioki/HK
Table Of Content
- Product Deatils
- Equipment layout
- Technical parameter
- The main accessories
- Machine Working
Product Details :
Equipment layout:
The automatic sorting equipment consists of an automatic feeder, test, automatic sorting, and material box receiver and so on. Manually put the integrated batteries into the buffer area of the automatic feeder, and the automatic feeder sends the cells to the testing area one by one. Put them into the corresponding grades; in this way, the main components and layout diagrams are as follows:
4.1 Technical parameter
1. Equipment operating environment requirements.
2. Operating temperature range: -10°C~40°C.
3. Humidity: ≤85%.
4. Site: no pollution and strong electromagnetic interference.
5. The maximum size of the equipment is Length: 1450mm; Width: 750mm; Height: 1500mm.
6. Total weight: 180kg.
7. Equipment electrical: AC220V±10% 50Hz; power consumption≤800W.
8. Compressed air: the pressure is 0.5 ~ 0.7Mpa.
4.2 System technical indicators.
1. Product damage probability: ≤0.01%.
2. Equipment capacity/speed: ≥2000pcs/h.
3. Failure rate of NG equipment: ≤ 2% (failure caused by equipment only).
4. Number of sorting files: 5 files.
5. Adapt to batteries: 32140 batteries.
6. Internal resistance detection accuracy: range 0-60 mΩ; accuracy ±0.5% rdg; resolution 0.1mΩ.
7. Voltage measurement accuracy: range 0-10V; basic accuracy ±0.015% rdg; resolution 0.1mV.
The main accessories :
S. No | configure | brand |
1 | cylinder | AIRTAC, CHELIC, SMC, CKD, HITOP, Xinyang, etc. |
2 | The electromagnetic valve | AIRTAC, CHELIC, SMC, CKD, HITOP, Xinyang, etc. |
3 | Linear Guides | Xinfei, HIWIN |
4 | relay | OMRON, Shanghai Electric |
5 | PLC | Raise |
6 | sensor | OMRON, SUNX, Chevening |
7 | button | Optical Division |
8 | indicator light | Optical Division |
9 | Tester | Hepu HK3561 |
Training
S. No. | Training content | Trainers | Training period (days) | training method |
1 | Device installation | Buyer’s Equipment Department | 0.5-1 | on-site |
2 | Equipment debugging | Buyer’s Equipment Department | 1-5 | on-site |
3 | Equipment operation and application | Buyer’s equipment department and related operators and users | 0.5-1 | on-site |
4 | Equipment Safety Matters | Buyer’s equipment department and related operators and users | 0.5-1 | on-site |
5 | Wear parts replacement | Buyer’s Equipment Department | 0.5 | on-site |
6 | Equipment failure analysis and treatment | Buyer’s Equipment Department | 1-2 | on-site |
7 | Equipment daily maintenance | Buyer’s equipment department and related operators and users | 1-2 | on-site |
Other requirements
- The appearance color of the equipment is international standard warm gray1C.
- from the outer wall of the machine1000mmMeasurement, equipment noise≤80db.